Dry transformers TSHL 160-2500 / 10 (6) 70.4 UZ

  • Valon-A LLC supplies dry transformers. Transformers with a capacity of 160 - 2500 kVA are produced for the nominal voltage of the primary winding - 6, 10 kV, secondary winding - 0.4, 0.23 kV.

     

    Dry-type power transformers TSGL 160-2500 kVA (6/10 kV → 0.4/0.23 kV) from LLC "Valon-A", Khmelnytskyi. Cast epoxy insulation, high reliability, PBV ±2×2.5%, IP20-IP22. Order and consultation. Delivery across Ukraine.

    LLC "Valon-A" is a Ukrainian manufacturer and supplier of electrical equipment and transformer substations, which offers dry-type power transformers of the TSGL series with a capacity from 160 to 2500 kVA. These are modern energy-efficient solutions for reliable transformation of electricity in networks 6/10 kV → 0.4/0.23 kV, meeting the requirements of industrial, municipal and commercial facilities.

     

    Dry-type transformers TSGL: purpose and application

     

    TSGL transformers are used in electricity distribution systems for:

    power supply enterprises;

    industrial enterprises;

    commercial and shopping centers;

    housing and communal services facilities;

    alternative energy systems;

    power equipment of KTP and other substations.

     

    This is the optimal solution where fire safety, environmental friendliness, low operating costs and a high service life are important.

     

    Technical characteristics of dry power transformers TSGL

    Capacity: 160 – 2500 kVA

    Primary winding voltage: 6 / 10 kV

    Secondary winding voltage: 0.4 / 0.23 kV

    Frequency: 50 Hz

    Connection schemes: U/Un-0 or D/Un-11

    Cooling: air, dry

    Housing protection degree: IP20, IP21 or IP22

    Heat resistance class of windings: F

    Cast epoxy insulation "Geofol" (ABB, Siemens, Schneider Electric, Tesar, Merlin Gerin, etc.)

     

    Design features and advantages of power transformers from LLC "Valon-A"

    Cast epoxy insulation - high fire resistance and mechanical strength;

    Oil-free design - environmental friendliness and no risk of oil leaks;

    Minimum maintenance requirements;

    Increased short circuit resistance;

    Low noise;

    Switching of branches without excitation (PBV) ±2×2.5%.

     

    Operating conditions of the TSGL transformer 160-2500 kVA (6/10 kV → 0.4/0.23 kV)

    Altitude up to 1000 m

    Temperature: –25°C…+40°C

    Atmosphere category II (according to GOST 15150)

    Climatic version U3

     

    Why choose TSGL transformers from "Valon-A"

    Reliable operation in complex power networks

    Durability and high efficiency

    Warranty and technical support

    Direct supply from the manufacturer

    Possibility of individual configuration and execution

     

    Khmelnytskyi

    +38 (097) 968-43-35

    +38 (0382) 74-86-00

LLC "Valon-A" is a Ukrainian manufacturer and supplier of electrical equipment and transformer substations, which offers dry-type power transformers of the TSGL series with a capacity from 160 to 2500 kVA. These are modern energy-efficient solutions for reliable transformation of electricity in networks 6/10 kV → 0.4/0.23 kV, meeting the requirements of industrial, municipal and commercial facilities.

 

Dry-type transformers TSGL: purpose and application

 

TSGL transformers are used in electricity distribution systems for:

power supply enterprises;

industrial enterprises;

commercial and shopping centers;

housing and communal services facilities;

alternative energy systems;

power equipment of KTP and other substations.

 

This is the optimal solution where fire safety, environmental friendliness, low operating costs and a high service life are important.

 

Technical characteristics of dry power transformers TSGL

Capacity: 160 – 2500 kVA

Primary winding voltage: 6 / 10 kV

Secondary winding voltage: 0.4 / 0.23 kV

Frequency: 50 Hz

Connection schemes: U/Un-0 or D/Un-11

Cooling: air, dry

Housing protection degree: IP20, IP21 or IP22

Heat resistance class of windings: F

Cast epoxy insulation "Geofol" (ABB, Siemens, Schneider Electric, Tesar, Merlin Gerin, etc.)

 

Design features and advantages of power transformers from LLC "Valon-A"

Cast epoxy insulation - high fire resistance and mechanical strength;

Oil-free design - environmental friendliness and no risk of oil leaks;

Minimum maintenance requirements;

Increased short circuit resistance;

Low noise;

Switching of branches without excitation (PBV) ±2×2.5%.

 

Operating conditions of the TSGL transformer 160-2500 kVA (6/10 kV → 0.4/0.23 kV)

Altitude up to 1000 m

Temperature: –25°C…+40°C

Atmosphere category II (according to GOST 15150)

Climatic version U3

 

Why choose TSGL transformers from "Valon-A"

Reliable operation in complex power networks

Durability and high efficiency

Warranty and technical support

Direct supply from the manufacturer

Possibility of individual configuration and execution

 

Khmelnytskyi

+38 (097) 968-43-35

+38 (0382) 74-86-00

" />

Banners